Introduction
SP PRO Configuration
The SP PRO is
configured by default to accept the Float input on Digital Control Input
This is set
to accept the Float signal from the Flexmax regulator.
Flexmax 60/80 Regulator
Configuration
The Flexmax 60/80 must be set to turn AUX Output on when in Float.
In MAIN menu, select AUX.
In AUX MODE press NEXT until Float is displayed.
Press MODE and set to Auto
Note: The
AUX MODE Float function is only active when the Flexmax is actually producing
power.
SP PRO and Flexmax Wiring
The AUX Output provides 12VDC which is compatible with the
SP PRO Digital Control Input.
1. Connect AUX+ to DGTL CTRL IN 1 POS
terminal on Expansion Card.
2. DGTL CTRL IN 1 NEG connects through to
AUX -
Note: Digital Inputs are independent
current limited inputs which are ‘opto’ isolated and reverse polarity protected.
Test Operation
In AUX MODE, press Mode to change from AUTO to ON. The SP PRO will also switch to Float
stage. If this doesn’t occur, check the
wiring and settings in both SP PRO and Flexmax.
Set Mode back to AUTO for normal operation.
Note: The
SP PRO will only switch back to initial when the battery voltage falls below
the Initial Return voltage.