Fitting Advanced Communications Card to SP PRO Series 2
NOTE: The Advanced Communications Card Installation kit is not suitable for SP PRO Series 1.
The following is a summary of the steps needed to complete the installation. Once the installation is completed, use the below points as a check list:
Install the latest version of SP LINK on your computer from http://www.selectronic.com.au
Connect to the SP PRO via the original green Comms Card using SP LINK software
Update the SP PRO firmware, selecting a firmware suitable for your AC coupled inverter if applicable
Install the Advanced Communications Card in the SP PRO
Update firmware in Advanced Communications Card using SP LINK
The SP PRO firmware must be the latest. You must install SP LINK on a Windows computer, connect to the SP PRO and update its firmware. This is done by following the steps below:
Leave the original green Comms Card in the SP PRO until the firmware update process is complete
Download the SP LINK software from the Selectronic web site and install it on a Windows PC. Windows XP, Vista, 7, 8.1 and 10 are supported. http://www.selectronic.com.au/splink
Connect the PC to the SP PRO via the supplied USB cable
Connect the DC power to the SP PRO. Wait until the SP PRO front panel LEDs are stable
Start Selectronic SP LINK.
At the Easy Start Guide, select Firmware Update...
The Easy Start Guide will automatically detect when the SP PRO is ON and USB cable is plugged into the SP PRO and computer.
Click Connect to start the SP PRO Firmware Update process.
In the SP PRO Firmware Update screen, click on the Upload firmware and restart SP PRO on completion button.
NOTE: Some batteries may turn themselves OFF during the firmware update. If this occurs, turn the batteries ON, close the SP PRO Firmware Update window and reconnect to the
SP PRO. Continue the firmware update, repeat the process until the firmware is updated.
- Verify the firmware has updated successfully. Once the SP PRO has restarted, wait another 20 seconds then click Connect again at the Easy Start Guide.
- The Upload firmware and restart SP PRO on completion button will now be disabled if the Current and New versions are the same.
- Disconnect SP LINK and power down the SP PRO inverter (All lights on the front panel will be OFF). The three blue lights across the top will still be lit if there is AC source power (grid or generator). This is OK.
Make sure that the SP PRO inverter is powered down (All Lights on the front panel will be off) The three blue lights across the top will still be lit if there is AC source power (grid or generator). This is OK.
Remove the 4 Torx screws holding the original green comms card in the SP PRO.
Do not throw away the Torx screws. These screws (mounting screws) will be used to remount the Advanced Communications Card.Remove the 2 short grey RJ45 connectors from the Control Board in the SP PRO. (Internal Communications Ports 1 and 2)
Remove the white, 2 pin plug on the top right corner of the green Comms Card (Power).
Remove the original green Comms Card.
Connect the white, 2 pin plug (power) to the top, right corner of the Advanced Communications Card.
Connect the two, small grey RJ45 leads to the Advanced Communications Card and into the Control board in the SP PRO (Internal Communications Ports 1 and 2).
Screw down the Advanced Communications Card into the SP PRO using the 4 Torx screws.
Updating Firmware in the Advanced Communication Card
Start Selectronic SP LINK.
Select Firmware Update...
The Easy Start Guide will automatically detect when the SP PRO is ON and USB cable is plugged into SP PRO and computer.
Click Connect to start the firmware update process.
- In the SP PRO Firmware update screen click on the “Upload firmware and restart SP PRO on completion” button.
NOTE: If firmware is already up to date then this button will be disabled.
SP PRO. Continue the firmware update, repeat the process until the firmware is updated.
- After the update is completed, the SP PRO will automatically restart. You will need to wait about 2.5 minutes for the Advanced Communications Card to restart. Communications with the SP PRO will be lost during this time.
- Verify the firmware has updated successfully. Once the SP PRO has restarted, wait another 20 seconds then click “Connect” again at the Easy Start Guide.
Make sure the Current Comms Card Version is 2.06 or higher, and matches the New version.
NOTE: If the Advanced Communications Card Firmware is up to date then the Upload firmware and restart SP PRO on completion button will be disabled (greyed out).
Selectronic web site: http://www.selectronic.com.au or contact the Selectronic Sales Team.